Epoxy fiberglass insulation tubes for transformer lead support and electrical insulation applications. High mechanical strength, excellent insulation properties and customized d...
Fiberglass wound tubes are composite insulation products manufactured using fiberglass cloth or fiberglass yarn as reinforcement and epoxy resin or other thermosetting resins as the matrix. They are produced through a winding process, followed by heat curing and subsequent machining.
Compared with ordinary plastic tubes, epoxy fiberglass wound tubes offer good electrical insulation properties, mechanical strength and dimensional stability. These characteristics make them suitable for certain electrical insulation and mechanical support applications in power equipment.
By adjusting the fiberglass layup direction, winding angle, resin system and wall thickness, manufacturers can customize the tube structure and performance according to specific application requirements.
In power transformers, fiberglass wound tubes can be used as lead insulation supports, tubular insulation structures and other customized insulation components, depending on the transformer design.

Transformer leads are important conductive components that connect the windings to bushings, terminals and other electrical components. Due to the compact internal structure of a transformer, the required electrical clearance must be maintained between leads at different electrical potentials and between leads and grounded structures.
During transformer operation, leads and their connection points may also be affected by several factors:
Electrical Stress: Different electrical potentials require reliable insulation structures.
Mechanical Stress: Transformer leads and connecting components must remain securely positioned to prevent unwanted movement.
Vibration and Shock: Vibration and mechanical impact may occur during transportation, installation and operation.
Temperature Variations: Changes in operating temperature may affect the performance and dimensional stability of insulation materials.
Therefore, properly designed insulation and support structures for transformer leads are important for maintaining electrical safety and mechanical stability inside the transformer.

Fiberglass wound tubes can be designed as tubular insulating support components within transformer lead systems.
By selecting suitable inner diameters, outer diameters, wall thicknesses and lengths, manufacturers can meet the structural requirements of specific installation positions.
In suitable transformer designs, these tubes can provide electrical insulation and mechanical support, helping maintain the designed position of conductors and the required electrical clearances between conductive components and surrounding structures.
Transformer internal leads usually need to be arranged and secured according to the designed routing. Without proper support, leads may move during transportation, installation or operation.
Epoxy fiberglass wound tubes offer rigidity and mechanical strength. In appropriate structural designs, they can serve as part of a lead support assembly to help maintain the position of transformer leads.
Depending on the assembly design, they can also be used together with insulating clamps, brackets and other insulation components.
Reliable electrical insulation is required between conductive components operating at different electrical potentials inside a transformer.
Fiberglass wound tubes have electrical insulation properties and, after appropriate design and performance verification, can be used as insulating sleeves or tubular insulation protection components in specific transformer lead assemblies.
Their actual insulation function must be determined according to the operating voltage, electrical clearance, electric field distribution and the overall transformer insulation system. The insulation rating cannot be determined solely from the tube’s appearance or material designation.
In addition to transformer lead insulation support, fiberglass wound tubes can also be designed for other positions requiring tubular insulation and mechanical support.
For example, certain customized insulating sleeves, support tubes and structural connection components can be manufactured from epoxy fiberglass composites.
Specific applications should be determined according to the transformer manufacturer’s drawings, installation space and performance requirements.
The combination of epoxy resin and fiberglass reinforcement forms a composite material with good electrical insulation properties.
When the relevant electrical design and testing requirements are satisfied, these tubes can be used in specific internal transformer insulation support structures.
Fiberglass reinforcement improves the mechanical properties of the tube, providing resistance to bending and compression as well as structural support.
By adjusting the fiber winding angle and layup structure, manufacturers can optimize product performance for different loading directions.
Properly cured and machined epoxy fiberglass tubes offer good dimensional stability, helping meet the dimensional accuracy and assembly requirements of internal transformer insulation components.
Fiberglass wound tubes can be manufactured with customized inner diameters, outer diameters, wall thicknesses and lengths. They can also undergo cutting, drilling and other machining operations.
This flexibility helps meet the design requirements of different transformer models and internal structures.
For transformer manufacturers, selecting the right fiberglass wound tube requires comprehensive consideration of product dimensions, mechanical properties, electrical performance and operating environment.
| Selection Factor | Key Considerations |
|---|---|
| Outer and inner diameter | Compatibility with lead installation and assembly requirements |
| Wall thickness | Insulation and mechanical design requirements |
| Tube length | Available installation space inside the transformer |
| Electrical properties | Dielectric strength, electrical clearance and design requirements |
| Mechanical properties | Bending strength, compressive strength and actual loading conditions |
| Thermal resistance | Suitability for the transformer’s operating temperature |
| Operating environment | Compatibility with transformer oil and other environmental conditions |
For products with special requirements, customers are encouraged to provide technical drawings, product dimensions, operating voltage, operating temperature and application environment. This information helps manufacturers evaluate the most suitable product specifications.
Xujue Electrical is a professional manufacturer of electrical insulation materials for transformers, motors, generators, and other electrical equipment.
To meet the different requirements of transformer manufacturers, we provide customized fiberglass wound tube solutions based on product dimensions, structural designs and machining requirements.
Customization options include:
Inner and outer diameters
Different wall thicknesses
Customized tube lengths
Fiberglass reinforcement structures and winding processes
Epoxy resin system selection
Cutting, drilling and other machining operations
If you are looking for epoxy fiberglass wound tubes for transformer lead insulation support, you are welcome to send Xujue Electrical your product drawings and technical specifications.
Our team can help evaluate material selection and product structure according to your specific application.

Xujue Electrical Fiberglass winding tube production workshop
Fiberglass wound tubes are composite materials that combine electrical insulation properties with mechanical support capabilities. With appropriate structural design and performance verification, they can be used for transformer lead insulation support, mechanical positioning and other tubular insulation applications.
For transformer manufacturers, selecting the right fiberglass wound tubes requires more than considering dimensions and mechanical strength. Electrical performance, operating temperature and compatibility with the actual working environment must also be evaluated.
Xujue Electrical provides fiberglass insulation tubes and other electrical insulation material solutions for transformer, motor and power equipment manufacturers.
Contact Xujue Electrical to discuss customized fiberglass wound tubes for transformer lead insulation support.
If you are interested in our products,, please send us a message and we will contact you as soon as we receive it. Email: info@ztaero.com whatsApp: +8616650273778
If you are attractive to our products, please send us a message and we will contact you as soon as we receive it.