Product Details
CKSC Series Dry Type Series Circuit Reactor | ||||||||
Rated Capacity (KVAR) |
Model | Circuit Rated Voltage (KV) |
Terminal Voltage(V) |
Terminal Current(A) |
Reactance Rate(%) |
Loss(W) | Accessory Capacitor Capacity(KVAR) |
Weight(KG) |
12 | CKSC-12/10-6 | 11 | 381 | 10.5 | 6 | 720 | 200 | 180 |
24 | CKSC-24/10-6 | 11 | 381 | 21.0 | 6 | 750 | 400 | 290 |
36 | CKSC-36/6-6 | 6.6 | 228 | 52.6 | 6 | 1050 | 600 | 350 |
36 | CKSC-36/10-6 | 11 | 381 | 31.5 | 6 | 1050 | 600 | 350 |
60 | CKSC-60/6-6 | 6.6 | 228 | 87.7 | 6 | 1650 | 1000 | 450 |
60 | CKSC-60/10-6 | 11 | 381 | 52.5 | 6 | 1650 | 1000 | 450 |
90 | CKSC-90/6-6 | 6.6 | 228 | 131.0 | 6 | 1800 | 1500 | 650 |
90 | CKSC-90/10-6 | 11 | 381 | 78.7 | 6 | 1800 | 1500 | 650 |
108 | CKSC-108/6-6 | 6.6 | 228 | 157.5 | 6 | 2350 | 1800 | 700 |
108 | CKSC-108/10-6 | 11 | 381 | 94.5 | 6 | 2350 | 1800 | 700 |
120 | CKSC-120/6-6 | 6.6 | 228 | 175.0 | 6 | 2750 | 2000 | 780 |
120 | CKSC-120/10-6 | 11 | 381 | 105.0 | 6 | 2750 | 2000 | 780 |
150 | CKSC-150/6-6 | 6.6 | 228 | 219.0 | 6 | 2860 | 2500 | 1050 |
150 | CKSC-150/10-6 | 11 | 381 | 131.2 | 6 | 2860 | 2500 | 1050 |
180 | CKSC-180/6-6 | 6.6 | 228 | 263.0 | 6 | 2950 | 3000 | 1250 |
180 | CKSC-180/10-6 | 11 | 381 | 157.5 | 6 | 2950 | 3000 | 1250 |
240 | CKSC-240/6-6 | 6.6 | 228 | 351.0 | 6 | 3450 | 4000 | 1450 |
240 | CKSC-240/10-6 | 11 | 381 | 210.0 | 6 | 3450 | 4000 | 1450 |
300 | CKSC-300/10-6 | 11 | 381 | 262.5 | 6 | 4260 | 5000 | 1650 |
360 | CKSC-360/10-6 | 11 | 381 | 315.0 | 6 | 4850 | 6000 | 2200 |
450 | CKSC-450/10-6 | 11 | 381 | 394.0 | 6 | 5430 | 7500 | 2400 |
600 | CKSC-600/10-6 | 11 | 381 | 525.0 | 6 | 5840 | 10000 | 3200 |
When the grid voltage is 20kv or 10kv, the transformer in this series can control the connection status between two windings on high voltage coil in each phase via conversion device, and realize voltage conversion through series or parallel connection without changing the output voltage, thus enabling one transformer to connect with two electrical voltage systems like 10kv or 20kv asynchronously, where the transformer acts as a transition of upgrading the grid voltage from 10kv to 20kv. In this way, it can achieve repeated investment reduction, efficient conversion, and stable performance.
Leave a message
Related Products
ZTELEC PRODUCT DISPLAY
- Power Transformers
- Transmission And Distribution Series
- Mining Explosion-proof Transformer
- Special-purpose Transformer
- Oil-immersed Transformer
- Dry-type Transformer
- Electrical Insulation Material
- Laminated insulation board
- Laminated insulation tube
- Electrical Insulation Rod
- Electrical Insulation Paper
- Flexible insulating film
- Insulating Fiber Glass products
- Insulating Varnish, Resin
- Enamel Insulated Wire
- Paper Covered Wire
- Enameled Flat Wire
- Enameled Round Wire