tel

Online service:+8613137718313

10KV Grade Amorphous Metal Oil-immersed Transformer S(B)H15-M-30~1600/10 series

10KV Grade Amorphous Metal Oil-immersed Transformer S(B)H15-M-30~1600/10 series

Voltage:0.4kv 38.5kv 20kv 10kv 6kv
Capacity:200kva 500kva 1250kva 2500kva
Type:Distribution transformer
Phase:3pha

Product Details

Except for copper conductors, low-voltage windings of oil-immersed transformers generally use a cylindrical structure with copper foil around the shaft; high-voltage windings use a multilayer cylindrical structure to make the winding'

10KV Grade Amorphous Metal Oil-immersed Transformer S(B)H15-M-30~1600/10 series 
Rated Capacity
(KVA)
Voltage Combination Connection Method Loss(W) No Load Current(%) Impendence Voltage(%) Weight
(Kg)
Dimension(mm)
(L×W×H)
HV(KV) LV(KV) No Load Load
(75℃)
30 11

10.5

10

6.3

6
0.4 Dyn11

Yyn0
33 630/600 1.5 4 410 920×850×830
50 43 910/870 1.2 520 1040×780×870
63 50 1090/1040 1.1 570 1010×810×880
80 60 1310/1250 1.0  640 1060×830×910
100 75 1580/1500 0.9 750 1140×830×860
125 80 1890/1800 0.8 830 1110×880×950
160 100 2310/2200 0.6 940 1130×880×1000
200 120 2730/2600 0.6 1090 1240×900×1020
250 140 3200/3050 0.6 1250 1290×900×1070
315 170 3830/3650 0.5 4.5 1470 1380×840×1110
400 200 4520/4300 0.5 1710 1420×920×1250
500 240 5410/5150 0.5 1990 1360×1040×1180
630 320 6200 0.3 2390 1530×1120×1310
800 360 7500 0.3 2760 1880×1210×1360
1000 450 10300 0.3 3240 2040×1520×1360
1250 530 12000 0.2 3820 2140×1520×1430
1600 630 14500 0.2 4620 2260×1540×1500

Environment of 10KV Grade Amorphous Metal Oil-immersed Transformer S(B)H15-M-30~1600/10 Series Usage:

Under normal media conditions, oil-immersed transformers or dry transformers can be used, such as industrial and mining enterprises, agricultural independent or attached substations, community independent substations, etc. The transformers to choose from are S8, S9, S10, SC (B)9, SC (B)10, etc.
Benefits of 10KV Grade Amorphous Metal Oil-immersed Transformer S(B)H15-M-30~1600/10 Series:
1, transformer oil insulation performance is good, good thermal conductivity, while transformer oil is cheap.
2, can solve the transformer large-capacity heat dissipation problemand and high voltage insulation problems.
Normal Conditions for Use of 10KV Grade Amorphous Metal Oil-immersed Transformer S(B)H15-M-30~1600/10 Series:
1, Indoor or outdoor snares at altitude snares up to 1000m.
2, Maximum ambient temperature, maximum daily average temperature of 40 degrees C, s.30 degrees C.
3, Maximum annual average temperature : 20 degrees C Minimum temperature - 25 degrees C.
4, Transformers operating under special conditions are available upon user requirements.